Control Valve

2017-05-11 vwalve By vwalve

In order to properly maintain the cleanliness of the Sump Section, the Sump tank is equipped with a Sump Pit Pump. Liquid residue will periodically gather within the sump pit. When the level of these residues becomes too high the Sump Pit Pump will automatically turn on and pump the residues which have gathered in the sump pit into the plants waste water system. The Sump Pit Pump is located directly on the Sump tank. The Sump Pit Pump is equipped with a differential pressure sensor which detects the residue level of the sump pit and activates when the level rises too high.
Illustration drawing as below:

air pump-control valve- flow chart drawing

The air pressure induced by the ascending liquid within the sensing tube is transmitted via nylon tubing to the diaphragm component located in the valve head. Upon receiving this pressure signal, the diaphragm triggers the air pilot valve, thereby controlling the opening and closing of the main valve.There are no air bubbles generated at the end of the sensing tube, and there is no need to worry about clogging issues. Maximum flow 30 SCFM and the Max. differential about 10″ WC.

Model numberAir pump compress air inlet port size:
APV0021/4 inch

This device is mainly applied to water accumulation in mine or sump pits. It can automatically control drainage according to liquid level without requiring power supply. It is primarily used in conjunction with pneumatic turbine submersible pumps and diaphragm pumps, enabling automatic start-stop operation of these two types of pumps, eliminating the need for manual intervention, and features simple installation and reliable performance. Moreover, as it is fully pneumatically controlled and does not consume electricity, it avoids potential hazards caused by electrical power.

air pump  valve
Model numbercontrol air inlet port size
APV0033/8 inch
APV0041/2 inch
APV0063/4 inch

We can supply a complete pneumatic pump system according to the schematic diagram above. The system includes a diaphragm pump, a base, a controller, a ball valve, a filter, a pressure regulator, and piping, etc. The pump outlet can be customized to NPT threads or ANSI standard flanges. The entire unit will be thoroughly commissioned before leaving the factory. Customers only need to choose a location, secure the base, and connect it to compressed air; the whole system can then operate. The model and specifications of the accompanying diaphragm pump are shown in the table below (ARO pump is available as vwalve pump):

Model Number() Max Flow (L/min)Max Head (m)Max Suction Lift (m)Outlet Pressure (kg)Diameter (DN)Inlet Diameter (in)Particle Diameter (MM)Air Consumption (m³/min)
VWA3-1522704.07151/41.50.36
VWA-2057704.57201/42.50.36
VWA-2557704.57251/42.50.36
VWA-32170845.488.4321/23.20.67
VWA-40170845.488.4401/23.20.67
VWA-50378.5845.488.4501/24.80.90
VWA-65378.5845.488.4651/24.80.90
VWA-80568845.488.4801/26.41.5~2.0
VWA-100568845.488.41001/26.41.5~2.0
VWA-1251041845.488.41253/49.43.0-4.0

Choose what you need and contact us, we are ready for answer your questions at any time.